Nepieciešama rokasgrāmata savam Steinel IS 140-2 Kustības detektors? Zemāk var apskatīt un bez maksas lejupielādēt PDF rokasgrāmatu latviešu valodā. Šim produktam pašlaik ir 0 bieži uzdotie jautājumi, 5 komentāri un 11 balsis ar vidējo produkta vērtējumu 18/100. Ja šī nav jūsu vēlamā rokasgrāmata, lūdzu, sazinieties ar mums.

Vai jūsu produkts ir bojāts, un rokasgrāmatā nav sniegts risinājums? Dodieties uz Repair Café, lai veiktu bezmaksas remontu.

Rokasgrāmata

Principle
Movement triggers lights, alarms and many other devices - for your convenience and safety. The integrated
pyroelectric infrared detector senses the invisible heat radiated from moving objects (people, animals, etc.).
The heat detected in this way is converted electronically into a signal that activates the load connected. Heat
radiation is not detected through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings
During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first
and use a voltage tester to check that the power supply is disconnected.
Installing this unit involves work on the mains voltage supply. This must therefore be carried out
in accordance with applicable national wiring regulations and electrical operating conditions.
(
D
- VDE 0100,
A
-ÖVE-ÖNORM E8001-1,
-SEV 1000)
Only use genuine replacement parts.
Do not dismantle the unit yourself. It must only be repaired by a specialist workshop.
Installation
L = live conductor (usually black or brown)
Connection with concealed wiring
N = neutral conductor (usually blue)
Connection with exposed wiring
PE = any protective earth conductor (green/yellow)
Attention: Loop the protective-earth conductor through if necessary. A mains power switch for turning the unit
ON and OFF may of course be installed in the mains supply lead. Important: Reversing the connections may
result in damage to the unit. Please note that the circuit must be protected by a 10 A circuit breaker.
Optimum mounting height: 2 m for wall mounting
Function
Twilight setting (factory setting: daylight operation at 2000 lux):
The sensor's response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to = daylight operation at approx. 2000 lux.
Control dial set to = night-time operation at approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be set to (daylight operation).
Time setting (factory setting: 8 sec.): Light 'ON' time can be set from 8 secs. to 35 mins.
Control dial set to – = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, we recommend selecting the shortest time.
Adjust detection zone at swivel mount
Reach can be adjusted to between 2 and 14 m by tilting the lens through 90°.
Swivelling for align-
ment on the wall.
Reach 1 – 14 m. Max. setting permits detection along the building wall
.
Using
adhesive shrouds, e.g. to mask out paths or neighbouring property. Important: The most reliable way of detect-
ing movement is to install the sensor so that it points across the direction in which a person would walk and by
ensuring that no obstacles (such as trees, walls etc.) obstruct the line of vision. Reach is restricted when you
walk straight towards the sensor.
Troubleshooting (Fault / Cause
Remedy
)
No power / Fuse faulty, not switched on
new fuse, turn power switch ON, check lead with voltage tester.
Will not switch ON / Surroundings still too bright
wait until response threshold is reached or adjust setting
/
Bulb faulty
change bulb /
Power switch OFF
switch on /
Detection zone not properly targeted
readjust.
Will not switch OFF / Permanent movement in the detection zone
adjust detection zone
. Keeps switching
ON/OFF / There is a light in the detection zone
change detection zone, increase distance
. Switches ON
when unwanted / Detecting cars on the road, for example
change detection zone, tilt sensor down.
Reach changing / Differing ambient temperatures
at low temperatures, shorten reach by tilting sensor
down; at high temperatures, tilt sensor up.
Declaration of conformity
This product complies with Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC and RoHS Directive
2002/95/EC.
Functional warranty
This STEINEL product has been manufactured with great care, tested for proper operation and safety in accordance
with applicable regulations and then subjected to random sample inspection. STEINEL guarantees that it is perfect
condition and proper working order. The warranty period is 36 months, starting from the date of sale to the con-
sumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own discretion. The warranty does not cover damage to wear parts,
nor does it cover damage or defects caused by improper treatment, maintenance or the use on non-genuine parts.
Further consequential damage to other objects shall be excluded. The warranty will only be honoured if the product
is sent to the appropriate Service Centre fully assembled and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's stamp).
Service:
Our Customer Service Department will repair faults not covered by warranty or after the warranty period. Please
send the product well packed to your nearest Service Centre.
ENGLISH
GB
18
13
7
8
79
10
11
12
710
11a
IS 140-2
i
109599501 02/2012_C
Lejupielādēt rokasgrāmatu latviešu valodā (PDF, 18.03 MB)
(Apsveriet ietekmi uz vidi un drukājiet šo rokasgrāmatu tikai tad, ja tas patiešām ir nepieciešami)

Vērtējums

Paziņojiet mums, ko jūs domājat par Steinel IS 140-2 Kustības detektors, novērtējot produktu. Vai vēlaties dalīties pieredzē ar šo produktu vai uzdot jautājumu? Ievadiet savu komentāru lapas apakšdaļā.
Vai esat apmierināts ar Steinel IS 140-2 Kustības detektors?
18%
82%
11 vērtējumi

Pievienoties sarunai par šo produktu

Šeit varat dalīties savās domās par Steinel IS 140-2 Kustības detektors. Ja jums ir jautājumi, vispirms rūpīgi izlasiet rokasgrāmatu. Rokasgrāmatu var pieprasīt, izmantojot mūsu saziņas veidlapu.

JEAN LION 11-03-2021
SVEIKS, MAN IR TAISNSTURA NERESIJAS TĒRAUDA MODELIS AR Bumbu, KURA Apakšā DARBOJAS KĀ SENSORS. ES NESAPROTU, KĀ TIEK AKTIVIZĒTAS FUNKCIJAS ŠIS IR MODELIS AR SAULI, MĒNESI UN PULKSTENI TIE IR BUTHESSTONYUPLOUNDA BUTUŠTOUNU PULKSTENI. MAN BŪS PAR TO, KA TAS NAKSTĪS IESLĒGTS 5 MN, PATEICOTIES, KAD ES NOSPIEDZU POGAS, IESLĒGTS SARKANĀ GAISMA UN MĒĢINĀJU TO REGULĒT, TAS VAIRS NEIZSLĒGAS.

atbildēt | Tas bija noderīgi (10) (Tulkojis Google)
Leroy Jean Luc 19-12-2020
Sveiki, pērku Steinel kustību detektoru purpura vads pievelkas uz ko

atbildēt | Tas bija noderīgi (8) (Tulkojis Google)
erik klerkx 07-01-2022
Vai man sensorā ir jāizurbj 5 mm caurums?

atbildēt | Tas bija noderīgi (6) (Tulkojis Google)
Dieter Gibbösch 31-08-2019
Vai kustību detektors Steinel iS 140-2 ir piemērots arī uzstādīšanai pie griestiem ārpusē (jumta pārkare)?

atbildēt | Tas bija noderīgi (5) (Tulkojis Google)
Van der Bij 11-08-2021
Nerunā ar viņu

atbildēt | Tas bija noderīgi (0) (Tulkojis Google)

Vairāk par šo rokasgrāmatu

Mēs saprotam, ka ir patīkami, ka jūsu Steinel IS 140-2 Kustības detektors ir papīra rokasgrāmata. Jūs vienmēr varat lejupielādēt rokasgrāmatu no mūsu vietnes un pats to izdrukāt. Ja vēlaties saņemt oriģinālo rokasgrāmatu, iesakām sazināties ar Steinel. Viņi varētu nodrošināt oriģinālu rokasgrāmatu. Vai meklējat sava Steinel IS 140-2 Kustības detektors rokasgrāmatu citā valodā? Izvēlieties vēlamo valodu mūsu mājaslapā un meklējiet modeļa numuru, lai redzētu, vai tas ir pieejams.

Specifikācijas

Zīmols Steinel
Modelis IS 140-2
Kategorija Kustības detektori
Faila veids PDF
Faila lielums 18.03 MB

Visas rokasgrāmatas par Steinel Kustības detektori
Citas Kustības detektori rokasgrāmatas

Rokasgrāmata Steinel IS 140-2 Kustības detektors

Saistītie produkti

Saistītās kategorijas